img

05) O-RAN Open Fronthaul CUS plane testing of VVDN/Xilinx O-DU sub-system using VIAVI TM500 O-RU Tester

Companies Participating
in this Scenario

VVDN

Xilinx

VIAVI

img
img
img

Testbed setup

VVDN developed O-DU Fronthaul solution

Xilinx FPGA based NIC card used for O-DU Fronthaul implementation

Third-party L1 stack to be integrated with VVDN Fronthaul

VIAVI TM500 O-RU Tester used for End to End validation of the solution

Device Under Test

  • VVDN developed O-DU Fronthaul solution based on O-RAN specification
  • Xilinx FPGA based NIC card used for O-DU Fronthaul implementation
  • VIAVI TM500 O-RU Tester used for End to End validation of the solution, which includes Open Fronthaul CUS-plane Interfaces

Test scenarios introduction

VVDN, Xilinx, and VIAVI partnered together to develop an O-DU solution.

The scenario demonstrates VVDN developing O-RAN O-DU Fronthaul solution on Xilinx based FPGA NIC card. VVDN Fronthaul testing of O-DU sub-system (CUS-plane) is done by using VIAVI O-RU emulator. A selection of tests demonstrates S-Plane PTP master validation and interoperability of the O-RAN Fronthaul interface. Validated Control and User Plane messages are transmitted by the O-DU and decoded correctly by the O-RU.

Testing Results/Summary

The tests successfully demonstrated the interoperability/interworking of flexible Fronthaul for O-DU:

Full bandwidth testing of CU plane

Test and plot IQ data spectrum for different bandwidths

Demonstrated IEEE1588 PTP Master validation:

CU plane validation with and without PTP sync

Measured Throughput Details:

Fronthaul configuration : 273 PRB, Two Sections (140 + 133), 4 - Layer

Compression Bitwidth Theoretical Throughput (in Gbps) Hardware Throughput (in Gbps)
8 5.870592 5.75
9 6.604416 6.5
10 7.33824 7.25
11 8.072064 8
12 8.805888 8.75
13 9.539712 9.5
14 10.273536 10.25
15 11.00736 11
16 11.741184 11.74

Future Plans:

Fronthaul integration with the L1 stack

Fronthaul for O-RU side

Benefits for the Industry

  • Customers are benefitted from the deployment-ready Fronthaul solution, which is fully aligned with the O-RAN specification.